Electrical Energy Audit in Pratama Tapan Hospital

Nanda Okta Putra, Universitas Islam Negeri Sultan Syarif Kasim Riau, Indonesia
Zulfatri Aini, Universitas Islam Negeri Sultan Syarif Kasim Riau, Indonesia
Dila Marta Putri, Institut Teknologi Bisnis Riau, Indonesia

Abstract


Hospitals, as large energy consumers, must adopt efficient energy-saving measures due to cost increases, regulations, and climate change concerns. In this study, an electrical energy audit was conducted at Pratama Tapan Hospital to identify energy-saving opportunities and recommend equipment replacements or technology upgrades. The primary objective was to determine the Energy Consumption Intensity (ECI) and analyze the potential for energy savings. The audit re-vealed an ECI value of 10.33 kWh/m²/year, highly efficient by ASEAN-USAID standards. However, 100% of rooms didn't meet the SNI 03-6197-2000 light intensity standard, causing discomfort. The study recommends installing specific light fixtures and adjusting lamp power to comply with the standard. These findings offer valuable insights for healthcare institutions striv-ing to achieve sustainability goals.

Keywords


energy audit, type D hospital, ECI, lighting

Full Text:

PDF

References


D. J. E. B. T. dan K. E. (EBTKE), “Hebat, Indonesia Salah Satu Negara Dengan Tingkat Efisiensi Energi Tertinggi!,” 2017. https://ebtke.esdm.go.id/post/2017/03/16/1593/indonesia.peringkat.23.konsumsi.energi.tertinggi.dunia#:~:text=Kamis%2C 16 Maret 2017 %7C 15%3A00 WIB %7C,%28AS%29%2C American Council for An Energy-Efficient Economy %28ACEEE%29 (accessed May 08, 2023).

A. Martin, “Audit Energi Sistem Tata Cahaya dan Tata Udara pada Basement dan Lantai 1 Toko Buku Pekanbaru,” JTM-ITI (Jurnal Tek. Mesin ITI), vol. 6, no. 2, 2022, doi: 10.31543/jtm.v6i2.762.

M. Dongellini, C. Marinosci, and G. L. Morini, “Energy audit of an industrial site: A case study,” Energy Procedia, vol. 45, pp. 424–433, 2014, doi: 10.1016/j.egypro.2014.01.046.

H. Mahmood, D. Michaelson, and J. Jiang, “Accurate reactive power sharing in an islanded microgrid using adaptive virtual impedances,” IEEE Trans. Power Electron., vol. 30, no. 3, 2015, doi: 10.1109/TPEL.2014.2314721.

A. A. Rahmawati and S. Abduh, “Audit Energi Gedung Kampus A Universitas Mu-hammadiyah Tangerang untuk Penerapan Sistem Manajemen Energi Berbasis ISO 50001 : 2018,” vol. 14, no. 2, pp. 187–195, 2023, doi: 10.33322/energi.v14i2.1715.

D. Despa, G. F. Nama, T. Septiana, and M. B. Saputra, “Audit Energi Listrik Berbasis Hasil Pengukuran dan Monitoring Besaran Listrik pada Gedung A Fakultas Teknik Unila,” Electrician, vol. 15, no. 1, 2021, doi: 10.23960/elc.v15n1.2180.

Y. N. Choir and D. Irawan, “Audit Energi Listrik Gedung Baru Universitas Muham-madiyah Gresik,” Power Elektron. J. Orang Elektro, vol. 12, no. 1, p. 8, 2023, doi: 10.30591/polektro.v12i1.4699.

S. Oktavia Ginting, I. B. G. Manuaba, and A. A. G. Maharta Pemayun, “AUDIT ENER-GI UNTUK PENCAPAIAN PENGHEMATAN PENGGUNAAN ENERGI LISTRIK DI PT. GRAHA SARANA DUTA II DENPASAR,” J. SPEKTRUM, vol. 9, no. 1, 2022, doi: 10.24843/spektrum.2022.v09.i01.p4.

A. Kumar, S. Ranjan, M. B. K. Singh, P. Kumari, and L. Ramesh, “Electrical Energy Audit in Residential House,” Procedia Technol., vol. 21, pp. 625–630, 2015, doi: 10.1016/j.protcy.2015.10.074.

A. Sendrayaperumal et al., “Energy Auditing for Efficient Planning and Implementa-tion in Commercial and Residential Buildings,” Adv. Civ. Eng., vol. 2021, 2021, doi: 10.1155/2021/1908568.

I. N. Darmawan, “Simulasi Audit Energi pada Rumah Sakit Umum Daerah Banyumas,” J-Proteksion, vol. 5, no. 2, 2021, doi: 10.32528/jp.v5i2.4130.

H. Eteruddin, A. Rahman, M. P. Halilintar, and A. Tanjung, “Evaluasi Indeks Konsum-si Energi Listrik Di Rumah Sakit Islam Ibnu Sina Pekanbaru,” J. Elektro dan Mesin Terap., no. Vol. 7 No. 2 (2021), 2021, doi: 10.35143/elementer.v7i2.5173.

M. Saputra and A. Hamzah, “Studi Analisis Potensi Penghematan Konsumsi Energi melalui Audit dan Konservasi Energi Listrik di Rumah Sakit Universitas Riau,” J. Online Mhs. Fak. Tek. Univ. Riau, vol. 4, no. 1, pp. 1–13, 2017.

S. Alhurayess and M. K. Darwish, “Analysis of energy management in hospitals,” 2012, doi: 10.1109/UPEC.2012.6398665.

S. Suhendar, “Audit Sistem Pencahayaan dan Sistem Pendingin Ruangan di Gedung Rumah Sakit Umum Daerah (RSUD) Cilegon,” Setrum Sist. Kendali-Tenaga-elektronika-telekomunikasi-komputer, vol. 2, no. 2, 2016, doi: 10.36055/setrum.v2i2.486.

B. S. N. (BSN), “SNI 03-6197-2000 Konservasi Energi Pada Sistem Pencahayaan,” 2000.




DOI: https://doi.org/10.21831/jee.v8i1.65277

Refbacks

  • There are currently no refbacks.


Copyright (c) 2024 Jurnal Edukasi Elektro

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Indexed by:

Supported by:

RJI Main logo

Lisensi Creative Commons

JURNAL EDUKASI ELEKTRO by Jurusan Pendidikan Teknik Elektro, Fakultas Teknik UNY distributed under a Creative Commons Attribution 4.0 International License based on the copyright of https://journal.uny.ac.id/index.php/jee/.